skip to Main Content

Hardwire Power Adapter

12 V / 150 W or 24 V / 150 W

Save

Save

Save

Hardwire Power Adapter 12V 150W
Hardwire Power Adapter 12V 150W

Hardwire Power Adapter

12 V / 150 W or 24 V / 150 W

About

A 150 W constant voltage hardwire power adapter. Accommodates either 100 ~ 240 VAC or 277 VAC power sources.

Order either 12 V / 150 W (in stock) or 24 V / 150 W (on request).

     

Save

Save

Save

FEATURES
Universal AC input / full range (up to 280 VAC)
IP65/IP67 level
Built-in active PFC function
Protections: Short circuit / Overload / Over voltage / Over temperature
Cooling by free air convection
OCP point adjustable through output cable or internal potential meter
Compliance to worldwide safety regulatins for lighting
Low cost, high reliability
Technical Information
12 V24 V
Input
Voltage Range 1100 ~ 240 / 277 VAC
Frequency Range47 ~ 63 Hz
Power FactorPF 0.95 / 230 VAC; PF 0.98 / 115 VAC at full load and rated output voltage; PF 0.9 at 75 ~ 100% load
Efficiency88%90%
AC Current2 A / 115 VAC; 1 A / 230 VAC
Inrush CurrentCold start 65 A / 230 VAC
Leakage Current< 1 mA / 240 VAC
Output
DC Voltage12 VDC24 VDC
Power150 W
Constant Current Region 29 ~ 12 V18 ~ 24 V
Rated Current11 A6.3 A
Rated Power132 W151.2 W
Ripple and Noise 3150 mVp-p
Voltage Adj Range 49 ~ 13 V22 ~ 27 V
Current Adj Range (adjustable by internal potential meter / output cable)5.5 ~ 11 A3.15 ~ 6.3 A
Voltage Tolerance 5± 2%± 1%
Line Regulation± .5%
Load Regulation± 1%± .5%
Setup, Rise Time3000 ms, 80 ms at full load 230 VAC / 115 VAC
Hold Up Time (Typ.)50 ms / 230 VAC; 16 ms / 115 VAC at full load
Protection
Over Current 695% ~ 108%
Short Circuit 7Hiccup mode, recovers automatically after fault condition is removed
Over Voltage 813.8 V ~ 16.2 V27.6 V ~ 32.4 V
Over Temperature 8100 °C ± 10 °C (RTH2)
Environment
Operating Temperature 9-30 °C ~ +55 °C at full load; +70 °C at 60% load
Storage Temperature-40 °C ~ +80 °C
Operating Humidity20% ~ 95% RH non-condensing
Storage Humidity10% ~ 95% RH
Temp. Coefficient± .03% / °C (0 ~ +50 °C)
Vibration10 ~ 500 Hz, 5G 12 minutes / 1 cycle, period for 72 minutes each along X, Y, Z axes
Withstanding Voltage I/P-O/P: 3.75 kVAC; I/P-FG: 1.88 kVAC; O/P-FG: 0.5 kVAC
Isolation ResistanceI/P-O/P, I/P-FG, O/P-FG: 100 M Ohms / 500 VDC / 25°C / 70% RH
EMI Conduction and RadiationCompliance to EN55015, EN55022 (CISPR22) Class B
Harmonic CurrentCompliance to EN61000-3-2 Class C ( 75% load) ; EN61000-3-3
EMS ImmunityCompliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN61547, EN55024, light industry level (surge 4KV), criteria A
Certifications 10UL1012 ; EN61347-1, EN61347-2-13 independent ; UL60950-1, TUV EN60950-1 (TBD)
Dimensions8 3/4” (222 mm) L x 2 11/16” (68 mm) W x 1 17/32” (39 mm) H
Additional
Mean Time Before Failure> 303 700 hours MIL-HDBK-217F (25 °C)
Packaging1.0Kg; 12 pcs / 13 Kg / 0.49 ft3 (CLG-150-A/B); 1 Kg; 12 pcs / 13 K / 0.96 ft3 (CLG-150-C)

Front View

Hardwire Power Adapter 12 V, 150 W

Profile View

Electrical Components

Derating Curve

Hardwire Power Adapter 12 V, 150 W Derating Curve Static Characteristics

Notes:

  1. Derating may be needed under low input voltages. Please check the derating curve for more details
  2. Constant current operation region is within 75% ~100% rated output voltage. This is the suitable operation region for LED related applications, but please
    reconfirm special electrical requirements for some specific system design
  3. Ripple & noise are measured at 20 MHz of bandwidth by using a 12″ twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor
  4. Type A and type C only
  5. Tolerance: Includes set up tolerance, line regulation and load regulation
  6. Constant current operation region is within 75% ~100% rated output voltage. This is the suitable operation region for LED related applications, but please
    reconfirm special electrical requirements for some specific system design. Protection Type: Constant current limiting, recovers automatically after fault condition is removed
  7. Refer to OLP characteristics
  8. Protection Type: Shut down o / p voltage, re-power on to recover
  9. Refer to derating curve
  10. Safety and EMC design refer to EN60598-1, subject 8750(UL), CNS15233, GB7000.1, FCC part18
Order Information

Order either 12 V / 60 W (in stock) or 24 V / 150 W (on request).

Please contact us for order information.

Downloads
COMPATIBLE PRODUCTS (12 V)
COMPATIBLE PRODUCTS (24 V)